Chinese Journal of Blood Purification ›› 2017, Vol. 16 ›› Issue (04): 258-260.doi: 10.3969/j.issn.1671-4091.2017.04.011

Previous Articles     Next Articles

Removal of β2- microglobulin during on- line hemodiafiltration using a domestic hemofilter

  

  • Received:2016-09-08 Revised:2016-11-15 Online:2017-04-12 Published:2017-04-12

Abstract: Objective To investigate the removal of serum β2-microglobulin during on-line hemodiafiltration using a domestic hemofilter. Methods In this single center, self-control, open-label clinical study, 30stable hemodialysis patients whose serum β2-microglobulin increased to more than 10 times above the upper
normal limit were chosen to receive post- dilution online hemodiafiltration using a domestic hemofilter(Lengthen, membrane area 1.4m2) or an imported hemofilter (Toray, membrane area 1.6m2). Reduction ratio (RR) of β2-microglobulin was assessed. Results The RR of serum ß2- microglobulin was similar after online hemodiafiltration using a Lengthen (71.729%± 7.393%) hemofilter and a Toray hemofiter (74.707%±7.889%, t=1.508, P=0.137). Conclusion There was a good removal effectiveness of ß2-microglobulin when the domestic hemofilter was used in post-dilution online hemodiafiltration.

Key words: Hemodiafiltration, β2-microglobulin, Domestic hemofilter